Hybrid PLC Terminal Equipment: PCKHB-331

System configuration

 

 

 

 

 



Features

Ø      Maximum data rate 192kbps(50kHz band width) in Ethernet channel.

Ø      Unnecessary to change the configuration from the existing analog PLC channel assignment.

Ø      The digital channel and the voice channel can exist together by the method of plug-in mounting,

Ø      Increase the digital channel easily by reserving the 50kHz bandwidth first.

Ø      Adopt the modem method for thunder resistance.

Ø      In construction, the rack is 2,300mm in height, 130mm in width, 300mm in depth.

Ø      Possible to correspond also to the standard rack size, which is 1,350mm in height, 520mm in width, 300mm in depth.


Technical data

 

ØFrequency band                    :    100kHz to 450kHz selectable with setting the switch.

ØUsing band                            :    5kHz to 50kHz selectable with setting the switch.

ØOutput power                        :    +27dBm at 1 to 4 voice line

                              +25dBm at 5 to 6 voice line

                              +22dBm at 7 to 8 voice line

                              * 3dBm low level for a digital channel

ØDigital data rate (Ethernet)

Moderation method           64QAM: 192kbps(50kHz band width) to 32kbps(10kHz band width)

                              32TCM:  128kbps(50kHz band width) to 32kbps(14kHz band width)

                              16TCM:  96kbps(50kHz band width) to 32kbps(18kHz band width)

ØDigital interface package

                                                     10/100Base-Tx (32kbps*N N: Max.6)

ØAnalog interface package

                                                     2W/4W analog voice (include DL, RG)

                                                     Narrow band voice: 0.3kHz to 2.3kHz

                                                     Wide band voice: 0.3kHz to 3.4kHz

                                                     (Change the voice bandwidth by setting the switch in the package)

ØPower supply

                                                     AC100V/AC200V, DC-24V, DC-48V, DC110V


Modulation and maximum data rate

The digital data is transferred by using the gap frequency band except the voice band.

The data rate is decided by the bandwidth of the gap frequency, and can use multi digital channels within the range.

It is possible to select the modulation by setting the switch according to the noise situation of the transmission line.

 

 

64QAM

32TCM

16TCM

Maximum data rate

192 kbps

128 kbps

96 kbps

Bandwidth and data rate

Bandwidth

(KHz)

Data rate

(Kbps)

Bandwidth

(KHz)

Data rate

(Kbps)

Bandwidth

(KHz)

Data rate

(Kbps)

10.0

32

14.0

32

18.0

32

18.0

64

26.0

64

34.0

64

26.0

96

42.0

96

50.0

96

34.0

128

50.0

128

---

---

42.0

160

---

---

---

---

50.0

192

---

---

---

---